Будь ласка, використовуйте цей ідентифікатор, щоб цитувати або посилатися на цей матеріал: http://lib.inmeds.com.ua:8080/jspui/handle/lib/2414
Повний запис метаданих
Поле DCЗначенняМова
dc.contributor.authorChepurnyi, Yu.-
dc.contributor.authorChernogorskyi, D.-
dc.contributor.authorKopchak, A.-
dc.contributor.authorPetrenko, O.-
dc.date.accessioned2020-11-19T09:35:05Z-
dc.date.available2020-11-19T09:35:05Z-
dc.date.issued2020-
dc.identifier.otherDOI 10.1016/j.jobcr.2020.01.006-
dc.identifier.urihttp://lib.inmeds.com.ua:8080/jspui/handle/lib/2414-
dc.description.abstractPurpose: To assess the clinical efficacy of custom made PEEK patient-specific implants in treatment of orbital wall defects. Methods: Forty-five patients with unilateral post-traumatic orbital wall defects were enrolled in the study. They underwent subsequent reconstructive procedures using PEEK patient-specific implants (PSI) or pre-bent titanium plates. All the patients were examined with the standardized algorithm, including local status examination, vision assessment and computer tomography (CT) with measurements of the orbital volume. A comparative analysis of the treatment outcomes in two groups of patients (pre-bent plates/PSI) was performed. Results: The study findings show an absence of any postoperative infection, inflamation or decreased visual acuity in either group. In PSI group, diplopia after surgery was absent in 82.1% of patients versus 70.6% of controls. The mean duration of surgery was 54.25 ± 16.8 min with PSI application and 82.9 ± 10.8 min with pre-bent plates. The mean difference between the intact and damaged orbital volume was 1.9 ± 1.4 cm3 in the control group versus 0.74 ± 0.6 cm3 in PSI group (р < 0.05). Conclusion: PEEK PSI demonstrated higher clinical efficacy in comparison to pre-bent plates in orbital wall reconstruction especially in restoring the volume and shape of the damaged orbit.uk_UK
dc.language.isoenuk_UK
dc.publisherJournal of Oral Biology and Craniofacial Researchuk_UK
dc.relation.ispartofseriesVolume 10, Issue 2;-
dc.subjectOrbital reconstructionuk_UK
dc.subjectPatient-specific implantsuk_UK
dc.subjectPEEKuk_UK
dc.titleClinical efficacy of peek patient-specific implants in orbital reconstructionuk_UK
dc.typeArticleuk_UK
Розташовується у зібраннях:Кафедра офтальмології

Файли цього матеріалу:
Файл Опис РозмірФормат 
Clinical efficacy of peek patient-specific implants in orbital reconstruction.pdf1.21 MBAdobe PDFПереглянути/Відкрити


Усі матеріали в архіві електронних ресурсів захищені авторським правом, всі права збережені.